6 - ADVANCED PROGRAMMING MODE
6600 / 6665
6.23 FLOW METER SIZE (F)
Not viewed in timeclock regeneration mode.
Press the button. This parameter is identified by the letter “F”. This option is used to set the flow meter size.
Seven settings are possible. The only possible setting is #1 for 6600/6700 valve family:
Standard 3/4” [F - - - - - 1]
6.24 MIxING VALVE LOCATION (8)
Not viewed in timeclock regeneration mode.
Press the button. This display is identified by the number “8”. This option is used to indicate where the
mixing valve is located. Three settings are possible:
No mixing valve [8 - - - - - 1]
Mixing valve before flow meter [8 - - - - - 2]
Mixing valve after flow meter [8 - - - - - 3]
6.25 SYSTEM TYPE (9)
With 6600/6700 valve family, the only possible setting is 4. [9 - - - - - 4]
6.26 PROGRAM LOCKOUT (PL)
Press the button. This display is identified by the letters “Pl”. This display is used to prevent certain
programming displays from being viewed or set. Two settings are available:
Protection cancelled [Pl - - - OFF]
Protection active [Pl - - - - On]
The program lockout can be cancelled by pressing the button
for 25 seconds.
ATTENTION: press the button for 25 seconds when the program lockout is not activated will erase
all previous display setting; the electronic will reset to default values. The electronic programming
will have to be completely redone.
ExITING THE ADVANCED PROGRAMMING MODE
Press again the button, the electronic comes back in service.
Note: for further information, please contact our technical support.