EasyManua.ls Logo

Fleck 6600 - 7 - Basic Programming Mode (6700;6765); 7.1 Inlet Water Hardness Setting; 7.2 Mixing Valve Hardness; 7.3 System Capacity Configuration

Fleck 6600
205 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6600 – 6665 – 6700 – 6765
E
N
G
L
I
S
H
22
7 - BASIC PROGRAMMING MODE
6700 / 6765
The valve is in service position. To enter in the basic programming
mode, push and hold the button for 5 seconds.
7.1. Water Hardness in °tH
Not viewed in timeclock regeneration mode
Ex.: 30 °tH [H - - - -30]
7.2. Water Hardness after mixing valve in °tH
Not viewed in timeclock regeneration mode
Ex.: 8 °tH [P - - - -8]
7.3. System capacity in m3 °tH
Not viewed in timeclock regeneration mode
Ex.: 60 m3 °tH [- - - -60]
7.4. Regeneration time
Not viewed in immediate regeneration mode
Ex.: 2:00 AM [ - -2:00 -]
Regeneration cycle time setting
7.5. Cycle #1
Ex.: 10 minutes [1 - - 10.0]
7.6. Cycle #2
Ex.: 60 minutes [1 - - 60.0]
7.7. Cycle #3
Ex.: 10 minutes [1 - - 10.0]
7.8. Cycle #4
Ex.: 12 minutes [1 - - 12.0]
7.9. Cycle #5
Only for 6 cycles mode
Ex.: Not used [5 - - OFF]
7.10. Cycle #6
Only for 6 cycles mode
Ex.: Not used [6 - - OFF]
Note: not viewed if cycle #5 is set on OFF]
Basic programming mode exit.
The valve returns in normal operation.
Note :
1. Push the button once
per display.
2. Option settings may be
changed by pushing the
and set buttons

Table of Contents

Related product manuals