7 - BASIC PROGRAMMING MODE
6700 / 6765
The valve is in service position. To enter in the basic programming
mode, push and hold the button for 5 seconds.
7.1. Water Hardness in °tH
Not viewed in timeclock regeneration mode
Ex.: 30 °tH [H - - - -30]
7.2. Water Hardness after mixing valve in °tH
Not viewed in timeclock regeneration mode
Ex.: 8 °tH [P - - - -8]
7.3. System capacity in m3 °tH
Not viewed in timeclock regeneration mode
Ex.: 60 m3 °tH [- - - -60]
7.4. Regeneration time
Not viewed in immediate regeneration mode
Ex.: 2:00 AM [ - -2:00 -]
Regeneration cycle time setting
7.5. Cycle #1
Ex.: 10 minutes [1 - - 10.0]
7.6. Cycle #2
Ex.: 60 minutes [1 - - 60.0]
7.7. Cycle #3
Ex.: 10 minutes [1 - - 10.0]
7.8. Cycle #4
Ex.: 12 minutes [1 - - 12.0]
7.9. Cycle #5
Only for 6 cycles mode
Ex.: Not used [5 - - OFF]
7.10. Cycle #6
Only for 6 cycles mode
Ex.: Not used [6 - - OFF]
Note: not viewed if cycle #5 is set on OFF]
Basic programming mode exit.
The valve returns in normal operation.
Note :
1. Push the button once
per display.
2. Option settings may be
changed by pushing the
and set buttons