4 - VALVE OPERATION
4.3 BUTTON FUNCTION
4.3.1 ExTRA CYCLE BUTTON
Pressing this button will initiate a manual regeneration.
1. With timeclock or meter delayed regeneration, an extra regeneration will occur at the set regeneration time.
Press this button for 5 seconds, a regeneration will force to occur immediately.
2. With meter immediate regeneration, an extra regeneration will occur immediately.
4.3.2 PROGRAM BUTTON:
This button is used by the installer during the valve programming. It is used to enter the programming modes,
and to go from one setting to the next one.
4.3.3 SET BUTTON: AND
This button is used to set the current time of day, adjust the parameter value during the valve programming and
the time remaining in a regeneration cycle.