Indicator LEDs and factory reset
button
17
For location of the indicator LEDs and the factory reset button, see Figure 7.1 View from
the rear, page 14.
17.1 Power/error indicator LED and factory
reset button
Note Do not hold down the factory reset button when connecting the camera to power.
Factory reset button
depression time
period
Indicator LED status Explanation
> 1 second A continuous red light When the factory reset button is released:
• A factory reset is executed.
• The main camera application is restarted.
• The indicator LED status resumes the status it
had before the button was depressed.
> 4 seconds A flashing red light When the factory reset button is released:
• A factory reset is executed.
• The main camera application is restarted.
• The camera’s IP settings are reset to the fac-
tory defaults (DHCP assigned).
• The indicator LED status resumes the status it
had before the button was depressed.
> 10 seconds A rapidly flashing red
light
When the factory reset button is released:
• A factory reset is executed.
• The camera’s IP settings are reset to the fac-
tory defaults (DHCP assigned).
• All added users are deleted.
• All passwords are deleted.
• The camera is restarted.
17.2 Power/error indicator LED and power
modes
Indicator LED status Explanation
A flashing blue light. Normal operation.
17.3 Ethernet communication indicator LED
Indicator LED status Explanation
A flashing green light The camera is connected to a network and the
network activity is indicated.
No light (i.e., it is switched off). The camera is not connected to any network.