C-1
D - Troubleshooting
This appendix presents common mechanical, power, and networking challenges and resolutions, and
also provides information about contacting FLIR Technical Support.
D.1 - Mechanical
After powering on, the PTU stops moving with a grinding noise.
If you have a payload attached:
- The payload may be too heavy. Try moving the payload closer to the center of rotation of the
affected axis and/or reducing the payload weight.
- The movement settings may be too aggressive. Reduce the upper speed limit and/or accelera-
tion.
If you do not have a payload attached, contact FLIR Technical Support.
D.2 - Power
The PTU-5 reset movements are different than other PTU models.
This is normal behavior; the PTO does not return to 0,0.
D.3 - Networking
Unable to determine the PTU IP address to access the onboard Web page.
If you are running Windows, use the PTU Finder tool included on the CD that shipped with your PTU.
If you are not running Windows, attach a serial device to the PTU host port and then issue the NI
command to query the IP address of the PTU.
PTU-E46 Web page controls are sluggish.
Adjust the speeds and/or step size by clicking the Set Arrow Step Size or Set Arrow Speed headers in
the PTU Control Web page, as described in the Pan-Tilt E Series Command Reference Manual.
Try closing other programs on your computer to free up resources.