72
System Does
Not Power Up
18 - 32V
Power
Available
Across
P1-A(+)
and
P1-C(-)
Check
Power Circuit
No
HCU
Power Switch
in OFF
Position
Yes
CEU Fan
Operating
Replace
CEU
Place
Power Switch
in ON Position
Yes
Problem
Corrected
Replace
HCU
No
Yes
No
Resume
Operation
Yes
Problem
Corrected
Replace
Sensor
Cable
No
Problem
Corrected
Replace
Gimbal
No
Problem
Corrected
Call FLIR Systems
Field Service
for Assistance
No
For All Other
Power Fault
Problems
Problem
Corrected
Resume
Operation
Yes
Open Host Platform
Input Power Circuit
Breaker and Leave
Open for 60 Secs.
Close
Circuit Breaker
Problem
Corrected
Yes
No
Yes
Yes
Yes
Start
Start
No
No
Figure 4-1. Power Fault Chart
Commercial in Confidence
Export Level 2
Issued to: AgustaWestland
CM Ref:4049
Valid on Day of Issue only.
Document will not be updated
Uncontrolled : 4256
Retrieval Date:07-Dec-10
Requested by Bower, Richard

Table of Contents