c WARNING: Actuators equipped with electrical devices (motors, controls) requiring field wiring
must be wired and checked for proper operation by a qualified tradesman.
c WARNING: Use of the product must be suspended any time it fails to operate properly.
a CAUTION: Do not use oversized motor overload heaters. Instead, look for the cause of the
overload.
a CAUTION: Do not operate the valve under motor operation without first setting or checking the
limit switch setting and motor direction.
a CAUTION: Do not force the declutch lever into the motor operation position. The lever returns to
this position automatically when the motor is energized.
a CAUTION: Do not depress the declutch lever during motor operation to stop valve travel.
a CAUTION: Do not use replacement parts that are not genuine Flowserve Limitorque parts, as
serious personal injury and/or damage to the actuator and valve may result.
a CAUTION: Do not lift actuator/gearbox or actuator/valve combinations with only the eye bolts in
the L120 actuator. These eye bolts are designed for lifting the L120 actuator only.
a CAUTION: Do not lift the actuator by handwheel.
4.2 Safety Practices
The following check points should be performed to maintain safe operation of the L120 actuator:
Eye bolts are designed for lifting only the actuator and not associated gearboxes or valves.
Mount motor on a horizontal plane, if possible. Preferably, keep the motor or limit switch compart-
ment from hanging down. This prevents head of grease from being against motor or switch seals.
Keep the switch compartment clean and dry.
Keep the valve stem clean and lubricated.
Set up periodic operating schedules for infrequently used valves.
Verify that all actuator wiring is in accordance with the applicable wiring diagram.
Carefully check for correct motor rotation direction. If the motor is driving the valve in the wrong
direction, interchange any two leads on the three-phase motor or switch the armature leads on DC
motors.
Use a protective stem cover. Check valve stem travel and clearance before mounting covers on rising
stem valves.
Verify that a locking nut tightly secures the stem nut and that the top thread of the lock nut is crimped
and staked in two places.
For the DC motor, keep the armature clean and periodically check brushes for proper contact and wear.
4.3 Actuator Preparation
NOTE: Replace all molded plastic conduit and top protectors (installed for shipping purposes only)
with pipe plugs when installation wiring is complete.