Insulation Tester
Insulation Test
21
To store the results of an insulation test:
1. Push
I to save the measurement results. The Tester assigns and
displays a sequential tag number to identify the measurement.
2. If the tag number is acceptable, push
I to store the data. If a different
tag convention is required, create a custom 4-character tag:
a. Notice that the active character is blinking on the display. This is the
first of the four characters available for tagging the test results.
Repeatedly push J K to cycle through the character positions.
b. At each character position use
L or M to assign a character (0-9, A-Z,
a-z).
c. Push
I to store the results.
View Test Results Stored in Memory (1537 only)
Note
Parameters not appropriate for a test are shown as NA or UNSPEC.
The Tester can store 99sets of test data, including:
•Tags
• Ramp on or off
• Insulation Resistance
• Timer reading at termination of test (Timer)
• Test Voltage Selected (TV)
• Actual Test voltage (V)
• Capacitance (C)
• Polarization Index (PI)
• Dielectric absorption ratio (DAR)
• Dielectric discharge (DD)
• T1, T2, T3 (time, voltage, current and resistance.)
• Test current (I)
• Reason for ending the test
• Limit – off or timer setting (1 to 99minutes) (T. Limit)