A AC iFlex Adjustment Procedure
See Table 14 for only the A ac iFlex adjustment steps. When the Product shows SAUE on
the LCD, calibration is complete.
Table 14. A AC iFlex Adjustment
Step Display Calibrator Output Operation
1.
C-26 STBY Push I
2.
C-27 STBY Push I
3.
C-28 STBY Push I
4.
C-29 STBY Push I
5.
C-30 STBY Push I
6.
C-31 STBY Push I
7.
C-32 STBY Push I
8.
C-33 STBY Push I
9.
C-34 STBY Push I
10.
C-35 0 V, 0 Hz
Push
11.
C-36 60 mV, 50 Hz
Push
12.
C-37 30 mV, 50 Hz
Push
13.
C-38 60 mV, 100 Hz
Push
14.
C-39 120 mV, 200 Hz
Push
15.
C-40 180 mV, 300 Hz
Push
16.
C-41 240 mV, 400 Hz
Push
17.
C-42 300 mV, 500 Hz
Push
18.
C-26 STBY Push e
19.
Save --- ---