724
Users Manual
ii
Using Resistance-Temperature Detectors (RTDs) ............................................... 23
Using Source Mode........................................................................................................ 26
Sourcing Electrical Parameters ................................................................................. 26
Simulating Thermocouples........................................................................................ 27
Simulating RTDs........................................................................................................ 27
Setting 0 % and 100 % Output Parameters ................................................................... 30
Stepping and Ramping the Output................................................................................. 30
Manually Stepping the Output................................................................................... 30
Auto Ramping the Output.......................................................................................... 31
Storing and Recalling Setups......................................................................................... 31
Calibrating a Transmitter................................................................................................ 32
Testing an Output Device............................................................................................... 34
Replacing the Batteries.................................................................................................. 35
Replacing the Fuse ........................................................................................................ 35
Maintenance................................................................................................................... 36
Cleaning the Calibrator.............................................................................................. 36
Service Center Calibration or Repair......................................................................... 36
Replacement Parts.................................................................................................... 37
Specifications................................................................................................................. 39
DC Voltage Measurement......................................................................................... 39
DC Voltage Source.................................................................................................... 39
DC mA Measurement................................................................................................ 39
Ohms Measurement.................................................................................................. 40
Ohms Source............................................................................................................. 40
Millivolt Measurement and Source*........................................................................... 41
Temperature, Thermocouples................................................................................... 41
Temperature, RTD Ranges, and Accuracies (ITS-90)............................................... 42
Loop Power Supply ................................................................................................... 43

Other manuals for Fluke 724

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 724 and is the answer not in the manual?

Fluke 724 Specifications

General IconGeneral
Temperature Range-10°C to 55°C
Thermocouple TypesJ, K, T, E, R, S, B, L, U, N
Current Measurement0 to 24 mA
Operating Temperature-10°C to 55°C
FunctionProcess calibrator
RTD TypesPt100, Pt500, Pt1000
Voltage Measurement0 to 10 V
Loop Power24 V DC
DisplayDual Display
Power Supply4 AA batteries
Resolution0.1 °C
Storage Temperature-20 °C to 60 °C
Battery Life25 hours
Relative Humidity0 % to 90 %
Safety ComplianceCSA C22.2 No. 1010.1:1992