Certifying Twisted Pair Cabling
29
Autotest Summary Results for Twisted Pair Cabling
Figure 13 describes the Autotest Summary screen.
Figure 13. Autotest Summary for Twisted Pair Cabling
amd77f.eps
A
PASS: All parameters are within limits.
FAIL: One or more parameters exceed the limit.
PASS*/FAIL*: One or more parameters are within the tester’s
accuracy uncertainty range, and the “*” notation is required by the
selected test standard. See “PASS*/FAIL* Results” on page 30.
B
Press K or L to scroll the screen.
C
If the test failed, press J for diagnostic information.
D
Action prompt for the screen. Use D A to highlight a
parameter; then press H.
E
E: The test passed.
i: The parameter was measured, but has no PASS/FAIL limit in the
selected test limit.
X: The test failed.
U: See “PASS*/FAIL* Results” on page 30.
F
The worst margin found for the test.