EasyManua.ls Logo

Fluke DTX Series - Page 45

Fluke DTX Series
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Certifying Coaxial Cabling
37
Autotest on Coaxial Cabling
1
Attach coaxial adapters to the tester and smart remote.
2
Turn the rotary switch to SETUP, then select Coaxial.
Set the following on the Coaxial tab:
Cable Type: Select a list of cable types; then select the
cable type to be tested.
Test Limit: Select the test limit required for the job.
The screen shows the last nine limits used. Press J
More to see other lists of limits.
3
Turn the rotary switch to AUTOTEST and turn on the
smart remote. Connect to the cabling, as shown in
Figure 18 or 19.
4
If a fiber module is installed, you may need to press
J Change Media to select Coax as the media type.
5
Press Pon the tester or smart remote. To stop the test
at any time, press
I.
6
The tester shows the Autotest Summary screen when
the test is complete (see Figure 20 on page 40). To view
results for a specific parameter, use
A D to
highlight the parameter; then press H.
7
To save the results, press N. Select or create a cable ID;
then press
N again.
Note
If you turn off the main or remote unit while the
two units are connected through coaxial adapters,
the unit will turn on again.