DTX Series CableAnalyzer
Users Manual
46
-continued-
Figure 24. Network Connectivity Results Screen (DHCP example for twisted pair)
amd06.eps
A
Speeds supported by the switch or hub: 10 Mbit, 100 Mbit, 1000
Mbit. The current speed is green. Arrows show the connection’s
duplex configuration:
B
PoE shows if you ran the Network Connectivity w/ PoE test and the
device appears to support Power over Ethernet. The tester requests
power from suspected PoE devices. shows if the device did
not supply power during the test.
SFP shows for a fiber link.
C
Crossover indicator (twisted pair only):
Green: either the cable is straight-through, or the cable is a
crossover and the hub or switch crossed pairs 12-36 (MDI on the
Negotiation Details screen).
Orange: the tester compensated for a crossover cable by crossing
pairs 12-36 (MDI-X on the Negotiation Details screen).
4
3
2
8
9
6
1
5
7