Performance Check, Front Panel Controls 2-3
PARAMETER VALUE/SETTING
Input A & B
Trigger Level AUTO
Trigger Slope POS
Impedance 1 MW
Attenuator 1x
Coupling AC
Filter OFF
Arming
Start OFF
Start Slope POS
Start Arm Delay 200 ms
Stop OFF
Stop Slope POS
Hold-Off
Hold-Off State OFF
Hold-Off Time 200 ms
Time-Out
Time-Out State OFF
Time-Out Time 100 ms
Statistics
Statistics OFF
No. of Samples 100
No.ofBins 20
Pacing State OFF
Pacing Time 20 ms
Mathematics
Mathematics OFF
Math Constants K=1, L=0, M=1
Limits
Limit State OFF
Limit Mode ABOVE
Lower Limit 0
Upper Limit 0
Burst
Sync Delay 200 ms
Start Delay 200 ms
Meas. Time 200 ms
Freq. Limit 300 MHz
Miscellaneous
Function FREQ A
Meas. Time 200 ms
Smart Time Interval OFF
Auto Trig Low Freq 100 Hz
Timebase Reference INT
Table 2-2 Default settings for functions and parameters.
KEY(S) DISPLAY NOTES P/F
STANDBY Off
Red standby LED On
(KeycommontoON)
ON Backlight On
Red standby LED Off
(Key common to
STANDBY)
INPUT A Input A:
Menu for setting Slope,
Coupling, Impedance
etc.
Man Trig xx mV
Trig Trig: xx mV
Menu for entering nu
-
meric values
0.123V Trig: 0.123 V
t (5 times) Trig: _ V
4.567 Trig: 4.567 V
t (5 times) Trig: _ V
8.9 Trig: 8.9 V
± Trig: -8.9 V
mV Trig: -8.9 mV
V Trig: -8.9 V
AUTOSET Menu disappears
INPUT B Input B:
Menu for setting Slope,
Coupling, Impedance
etc.
SETTINGS Settings:
Menu for setting Meas
Time, Hold-Off, Ref.
Source etc.
ENTER Meas Time: 200 ms
p Meas Time: 500 ms
q Meas Time: 200 ms
EXIT/OK Settings:
Menu for setting Meas
Time, Hold-Off, Ref.
Source etc.
EXIT/OK Menu disappears
MATH/LIM Math/Limit:
Menu for selecting
post-processing for
-
mula and alarm limit
USER OPT User options:
Menu for Calibration,
Memory Management,
Interface etc.
CANCEL Menu disappears
HOLD/RUN Hold
At upper right corner
HOLD/RUN Hold disappears
MEAS FUNC Measure function:
Menu for selecting
measurement function
u Period
Cursor position marked
by text inversion
ENTER Single A
EXIT/OK Menu disappears
Period Single A: at up
-
per left corner
STAT/PLOT Period Single A
MEAN:
Aux parameters: Max,
Min, P-P, Adev, Std
VALUE Stat parameters dis
-
appear
Table 2-3 Keyboard test.