24
TS52PRO Test Set
Users Guide
Specifications
Electrical
Current Range
(Off-Hook)
10 mA to 100 mA
DC Resistance
Off-Hook 150 Ω nominal
On-Hook >3 MΩ
AC Impedance
Off-Hook 600 Ω nominal; 300 Hz to
3400 Hz
On-Hook >120 kΩ; 300 Hz to 3400 Hz
Rotary Dial Output
Pulsing Rate 10 pps ±1 pps
Break/Make Ratio 60/40
Interdigit Interval >300 ms
Resistance During
Break
>100 kΩ
DTMF Output
Tone Frequency
Error
±1.5 % maximum
Tone Level -3 dBm combined (typical)
High versus Low
Tone Difference
2 dB ± 2 dB
Memory Dialing
Memory Capacity 10 speed dial memories plus
one last number redial
memory
Digit Capacity 23 digits per memory
PBX Pause
Duration
4 seconds
Hook Flash
Duration
User programmable; default
of 600 ms
Automatic Speaker
Shut Off Duration
User programmable; default
of 2 minutes
Battery 9 V alkaline battery
Physical
Measurement 10 in x 3.75 in x 4.25 in
(254 mm x 96 mm x 107 mm)
Weight Less than 1.5 pounds (0.68 kg)
with one belt clip
Water Resistance Designed to be rain and
moisture resistant
Environmental
Temperature
Range
Handset speech
and dialing
functions
-22°F to 140 °F (-30°C to 60°C)
LCD function -13°F to 140°F (-25°C to 60°C)
Storage -22°F to 150°F (-30°C to 66°C)
Altitude To 10,000 ft. (3,000 m) max
Relative Humidity 95% to 30°C
75% to 40°C
45% to 50°C
30% to 60°C
Safety
Regulatory
Compliance
Complies with ANSI/ISA
82.02.01 (61010-1) 2004, CAN/
CSA-C22.2 No 61010-1-04, UL
61010-1 (2004) and IEC/EN
61010-1 2nd Edition for
measurement Category I, 300
Vdc Max, Pollution Degree 2
Maximum
Transient Voltage
1500V
EMC Complies with EMC EN61326-
1
Note
Specifications subject to change without notice.