Program Program
Code Function Code Description Entry Code
8 Issue/Rev. 03 (8/97)
017 D/C Output Relay 3 Enter: "00" No Assignment (N/A) 017
Terminals 13 & 12 "01" Additive Relay 1 (ADD1)
on Quad OPV "02" Additive Relay 2 (ADD2)
"03" Additive Relay 3 (ADD3)
"04" Additive Relay 4 (ADD4)
"05" Additive Relay 5 (ADD5)
"06" Additive Relay 6 (ADD6)
"07" Additive Relay 7 (ADD7)
"08" Additive Relay 8 (ADD8)
"09" Pulse Output (POT3) __ __
Note: This code is only available for use if the Quad OPV option has been purchased with the AccuLoad II.
018 D/C Output Relay 4 Enter: "00" No Assignment (N/A) 018
Terminals 17 & 16 "01" Additive Relay 1 (ADD1)
on Quad OPV "02" Additive Relay 2 (ADD2)
"03" Additive Relay 3 (ADD3)
"04" Additive Relay 4 (ADD4)
"05" Additive Relay 5 (ADD5)
"06" Additive Relay 6 (ADD6)
"07" Additive Relay 7 (ADD7)
"08" Additive Relay 8 (ADD8)
"09" Pulse Output (POT4) __ __
Note: This code is only available for use if the Quad OPV option has been purchased with the AccuLoad II.
019 A/C Input 1 Enter: "00" No Assignment (N/A) 019
Terminals 98 & 101 "01" Additive Feedback 1 (AFB1)
"02" Additive Feedback 2 (AFB2)
"03" Additive Feedback 3 (AFB3)
"04" Additive Feedback 4 (AFB4)
"05" Additive Feedback 5 (AFB5)
"06" Additive Feedback 6 (AFB6)
"07" Additive Feedback 7 (AFB7)
"08" Additive Feedback 8 (AFB8)
"09" First/Second High Flow (FSC)
"10" Printer Tray Switch (PTS)*
"11" Permissive 1 Contact (PRC1)
"12" Permissive 2 Contact (PRC2)
"13" Valve Power (VPW)
"14" Valve Stem-Product 1 (VST1)
"15" Valve Stem-Product 2 (VST2)
"16" Valve Stem-Product 3 (VST3)
"17" Valve Stem-Product 4 (VST4) __ __
*
Note: Or can be used for Master Reset.