Program 
Code 
 
Function Code 
 
 Description 
 
Entry 
Program
Code
 
72  Issue/Rev. 03 (8/97) 
__55  Recipe Correction   Enter:  Five digits as one whole number    __55 
  Factor    followed by four decimals 
      (e.g., 1.1000)  __. __ __ __ __ 
 
 
__80  Clean Line  Enter:  "0" Not Used     __80 
  Deduct    "1" Product 1 
      "2" Product 2 
      "3" Product 3 
      "4" Product 4  __ 
 
 
__81  Additive Injector  Enter:   Three digits in whole units    __81 
  Pulser No. 1    of delivered liquid per injector pulse  
      (e.g., 040)  __ __ __ 
 
 
__82  Additive Injector  Enter:   Three digits in whole units    __82 
  Pulser No. 2    of delivered liquid per injector pulse  
      (e.g., 040)  __ __ __ 
 
 
__83  Additive Injector  Enter:   Three digits in whole units    __83 
  Pulser No. 3    of delivered liquid per injector pulse  
      (e.g., 040)  __ __ __ 
 
 
__84  Additive Injector  Enter:   Three digits in whole units    __84 
  Pulser No. 4    of delivered liquid per injector pulse  
      (e.g., 040)  __ __ __ 
 
 
__85  Additive Injector  Enter:   Three digits in whole units    __85 
  Pulser No. 5    of delivered liquid per injector pulse  
      (e.g., 040)  __ __ __ 
 
 
__86  Additive Injector  Enter:   Three digits in whole units    __86 
  Pulser No. 6    of delivered liquid per injector pulse  
      (e.g., 040)  __ __ __ 
 
 
__87  Additive Injector  Enter:   Three digits in whole units    __87 
  Pulser No. 7    of delivered liquid per injector pulse  
      (e.g., 040)  __ __ __ 
 
 
__88  Additive Injector  Enter:   Three digits in whole units    __88 
  Pulser No. 8    of delivered liquid per injector pulse  
      (e.g., 040)  __ __ __