Do you have a question about the FMC Technologies AccuLoad II and is the answer not in the manual?
Brand | FMC Technologies |
---|---|
Model | AccuLoad II |
Category | Controller |
Language | English |
Configures essential system-wide parameters.
Defines the number of products the system supports.
Assigns specific functions to output relay 1.
Configures input signals for terminal 1.
Specifies product connections for additive injector 1.
Sets typical input/output configuration for selected products.
Sets the volume threshold for initiating low flow.
Defines the rate for the first high flow condition.
Configures the limit for overrun alarm activation.
Sets the volume of product to remain in the clean line.
Adjusts blend response time for flow rates.
Selects transaction control method (e.g., Print Key).
Sets the upper limit for preset volume.
Configures automatic preset volume functionality.
Defines allowable percentage tolerance for blends.
Selects units for temperature measurement (Fahrenheit/Celsius).
Sets the reference temperature for calculations.
Configures units for density measurement.
Sets the threshold for high density alarm.
Selects units for pressure measurement (Psi, Bar, Kgcm).
Sets the threshold for low pressure alarm.
Sets the threshold for high pressure alarm.
Selects method for calculating vapor pressure.
Configures EIA-232 communication interface type.
Sets control parameters for EIA-232 communication.
Configures EIA-485 communication interface type.
Identifies the unit location for communications.
Defines conditions for stopping additive injection.
Chooses between manual or auto injector operation.
Configures the first permissive condition for operation.
Sets a message for additive #1 on the product receipt.
General configuration settings for products.
Controls flow parameters specific to products.
Manages volume accuracy settings per product.
Configures temp/density parameters for products.
Sets communication parameters for products.
Configures product-specific I/O settings.
Sets the percentage limit for excess flow rate.
Defines the rate that prevents valve opening.
Configures the timer for zero flow detection.
Sets security for flow control valve operations.
Sets the minimum volume for a batch.
Defines the meter factor for product 1.
Sets the reference temperature for meter factor variation.
Applies master factor to restrict other meter factors.
Selects API tables for specific products.
Sets the reference density value.
Configures the alarm threshold for low temperature.
Sets the threshold for high density alarm.
Defines classification text for printouts.
Protects specific program codes.
Protects specific program codes.
Assigns a name to the blend recipe.
Classifies the blend recipe by product.
Sets the percentage for product 1 in a blend.
Specifies product connections for injector 1.
Configures pulser settings for additive injector 1.