Program       Program 
Code Function Code  Description  Entry  Code 
 
Issue/Rev. 0.3 (8/97)  27
209  Start Delay After Stop  Enter:  Three digits in whole seconds    209 
      of delay time from when the "STOP" 
      is pressed until the "START" can be  
      pressed. (e.g., 020)  __ __ __  
 
 
210  Pump Relay Time   Enter:  Two digits in seconds of    210 
  Delay    delay time for opening the pump 
      relay after "STOP". 
      (e.g., 09)  __ __  
 
 
211  Valve Delay To Open  Enter:  Two digits in seconds of    211 
      delay time to open the valve 
      after "START" is pressed. (e.g., 07) 
      "00" disables option  __ __  
 
 
212  Zero Flow Alarm  Enter:  "0" Zero Flow Alarm Disabled    212 
      "1" Zero Flow Alarm Enabled  __ 
 
Note: This code applies to RBU-08 and above firmware. 
 
 
213-239  Unassigned at Present  213-239 
 
 
240  Protection of Program  Enter:  "0" for Weights and Measures Mode    240 
  Codes 280-289    "1" for Program Mode  __  
 
 
280  Clean Line Product  Enter:  "1" for Product 1    280 
      "2" for Product 2 
      "3" for Product 3 
      "4" for Product 4  __ 
 
Note: If a recipe of 100% of the Clean Line Product is being loaded the AccuLoad II will not shut down and restart to add the Clean Line Product.  
This note applies to RBU-08 and above firmware.
 
 
 
281  Clean Line Volume  Enter:  Three digits in whole    281 
      units of product to be left 
      in the clean line at the end of 
      the batch. (e.g., 050)  __ __ __