Program Program
Code Function Code Description Entry Code
Issue/Rev. 0.3 (8/97) 27
209 Start Delay After Stop Enter: Three digits in whole seconds 209
of delay time from when the "STOP"
is pressed until the "START" can be
pressed. (e.g., 020) __ __ __
210 Pump Relay Time Enter: Two digits in seconds of 210
Delay delay time for opening the pump
relay after "STOP".
(e.g., 09) __ __
211 Valve Delay To Open Enter: Two digits in seconds of 211
delay time to open the valve
after "START" is pressed. (e.g., 07)
"00" disables option __ __
212 Zero Flow Alarm Enter: "0" Zero Flow Alarm Disabled 212
"1" Zero Flow Alarm Enabled __
Note: This code applies to RBU-08 and above firmware.
213-239 Unassigned at Present 213-239
240 Protection of Program Enter: "0" for Weights and Measures Mode 240
Codes 280-289 "1" for Program Mode __
280 Clean Line Product Enter: "1" for Product 1 280
"2" for Product 2
"3" for Product 3
"4" for Product 4 __
Note: If a recipe of 100% of the Clean Line Product is being loaded the AccuLoad II will not shut down and restart to add the Clean Line Product.
This note applies to RBU-08 and above firmware.
281 Clean Line Volume Enter: Three digits in whole 281
units of product to be left
in the clean line at the end of
the batch. (e.g., 050) __ __ __