Program Program
Code Function Code Description Entry Code
32 Issue/Rev. 03 (8/97)
400 System Temperature & Density Directory 400
401-439 Unassigned at Present 401-439
440 Protection of Program Enter: "0" for Weights and Measures Mode 440
Codes 480-489 "1" for Program Mode __
441 Temperature Units Enter: "0" No Temperature Used 441
"1" Fahrenheit
"2" Celsius __
442 Reference Enter: Four digit reference 442
Temperature temperature in tenth degrees
(e.g., 060.0) __ __ __ . __
443 Density Units Enter: "0" No Density Units 443
"1" Lbs/Ft
3
.
"2" Kgs/M
3
. __
444 Volume/Mass Enter: "0" Gallons per Density Units 444
Conversion "1" Dekaliters per Density Units
"2" Liters per Density Units
"3" Barrels per Density Units
"4" Cubic Meters per Density Units __
445 Mass Units Enter: Three character message 445
identifying the mass units
(e.g., Lbs) __ __ __
446-499 Unassigned at Present 446-499