Program Program
Code Function Code Description Entry Code
Issue/Rev. 0.3 (8/97) 31
350 Combinated Pulse Enter: "0" Raw Pulse Output 350
Output "1" Gross Pulse Output
"2" Gross @ Standard
Temperature Output
"3" Net Output
"4" Mass Output __
Note: This code applies to RBU-02 and above firmware.
351 Combinated Pulse Enter: Six digits defining the 351
Output Resolution pulse output resolution
(units/pulse) in thousandths
of units, 000.000 disables
this feature (e.g., 010.0) __ __ __ . __ __ __
Note: This code applies to RBU-02 and above firmware.
352 Combinate Pulse Enter: Three digits representing 352
Frequency will be output by the
combinated pulse output.
The range of this code is
004 to 999 (e.g., 500 Hz.). __ __ __
Note: This code applies to RBU-02 and above firmware.
353 Resolution of Enter: "0" Whole Units 353
Volumetric Totals "1" Tenth Units
on a Printed Report "2" Hundredth Units __
Note: This code applies to RBU-08 and above firmware.
354 Number of Batches Enter: A single digit representing the 354
per Transaction number of batches allowed to be
run per transaction. The range of
this code is 1 through 6 (e.g., 1) __
Note: This code applies to RBU-11 and above firmware.
355-389 Unassigned at Present 355-389
390 Input Pulse Type Enter: "0" Active Pulse Input 390
"1" Contact Type Input __
391-399 Unassigned at Present 391-399