Program       Program 
Code Function Code  Description  Entry  Code 
 
30  Issue/Rev. 03 (8/97) 
343  Display Resolution  Enter:  "0" Whole Unit Display    343 
      "1" Tenth Unit Display  
      "2" Hundredth Unit Display  
      "3" Tens Unit Display  __ 
 
 
344  Proving Modes  Enter:  "0" Not Proving    344 
      "1" Weights and Measures Proving  
      "2" High-Speed Proving  __ 
 
 
345  Proving Output  Enter:  "0" No Prover Output    345 
      "1" Product #1 Prover Output  
      "2" Product #2 Prover Output 
      "3" Product #3 Prover Output 
      "4" Product #4 Prover Output  __ 
 
 
346  Proving Output Units  Enter:  "0" Raw Prover Output (Raw)    346 
      "1" Gross Prover (Grs)  
      "2" Gross Prover at Standard Temperature (Gst)  
      "3" Gross Prover at Standard Temperature  
         and Pressure Preset (Net)  
      "4" Mass Preset (Whole Units)  __ 
 
 
347  Recipes Per  Enter:  "0" Single Recipe/Transaction    347 
  Transaction    "1" Multiple Recipes/Transaction  __ 
 
 
348  Blend Tolerance  Enter:  Two digits in tenths of a    348 
  (Percentage)    percentage for the tolerance allowed 
      for all delivered blends.  
      (e.g., 5.0 = 5 %)  __ . __ 
 
Note:  The larger of the tolerances as calculated using the percentage entered in this code or the volume entered in code 349 will be used to 
determine when a blend alarm should be triggered.
 
 
 
349  Blend Tolerance  Enter:  Three digits of Volume for    349 
  (Volume)    Blend Tolerance in tenths of units. 
      (e.g., 10.0)  __ __.__ 
 
Note:  The larger of the tolerances as programmed in this code or calculated in code 348 will be used to determine when a blend alarm should be 
triggered.