Program       Program 
Code Function Code  Description  Entry  Code 
 
26  Issue/Rev. 03 (8/97) 
200  System Flow Control Directory 200 
 
 
201  Low Flow Start Volume  Enter:  Four digits in whole    201 
      units (e.g., 0100)  __ __ __ __ 
 
Note:  The larger of the volumes as programmed in this code or calculated in code 202 will be used as the low flow start volume. 
 
 
202  Low Flow Start  Enter:  Two digits in whole percentage    202 
  Percentage    indicating the percentage of the preset  
      to be delivered during low flow start 
      (e.g., 10%)  __ __ 
 
Note:  The larger of the volumes as calculated using the percentage entered in this code or the volume entered in code 201 will be used as the low 
flow start volume.
 
 
 
203  Low Flow Start Rate  Enter:  Four digits in whole    203 
      units per minute (e.g., 0150) 
      "0000" entry will not allow 
      the valve to open.  __ __ __ __ 
 
 
204  Low Flow Start  Enter:  "0" Low Flow Start always after    204 
          zero flow.   
      "1" Low Flow Start at beginning 
          of batch only.  ___ 
 
 
205  System First High  Enter:  Four digits in whole units    205 
  Flow Rate    (e.g., 0600) "0000" Entry will not 
      allow the valve to open.  __ __ __ __ 
 
 
206  System Second High  Enter:  Four digits in whole units     206 
  Flow Rate    (e.g., 0300) "0000" Entry will not  
      allow the valve to open if configured  
      for 1st/2nd High Flow.  __ __ __ __ 
 
 
207  Overrun Alarm Limit  Enter:  Two digits in whole    207 
      units (e.g., 15)  
      "00" disables the alarm  __ __  
 
 
208  Zero Flow Timer  Enter:  Two digits in seconds (e.g., 15)    208 
      "00" disables this option  __ __