Program
Code
Function Code
Description
Entry
Program
Code
67 Issue/Rev. 03 (8/97)
Blend Recipe Directories
__00 Blend Recipe # __ Directory __00
__01 Blend Recipe Enter: "0" Recipe disabled __01
"1" Recipe enabled __
__02 Blend Recipe Name Enter: Up to nine characters for __02
recipe identifier. _______________
__03 Recipe Raw Non-resettable To be read only None __03
Volume
__04 Recipe Gross Non-resettable To be read only None __04
Volume
__05 Recipe Gross at Standard To be read only None __05
Temp. Non-resettable Volume
__06 Recipe Net Non-resettable To be read only None __06
Volume
__07 Recipe Mass Non-resettable To be read only None __07
Total
__08 HM Classification Enter: "1" Product 1 __08
"2" Product 2
"3" Product 3
"4" Product 4 __
__09 Minimum Preset To be read only __09
__10 Product #1's high, To be read only __10
2nd high and low flow rates
__11 Product #2's high, To be read only __11
2nd high and low flow rates