EasyManua.ls Logo

FMC Technologies AccuLoad II - Product #1 Percentage (__43)

Default Icon
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Program
Code
Function Code
Description
Entry
Program
Code
68 Issue/Rev. 03 (8/97)
__12 Product #3's high, To be read only __12
2nd high and low flow rates
__13 Product #4's high, To be read only __13
2nd high and low flow rates
__14-__39 Unassigned at Present __14-__39
__40 Protection of Program Enter: "0" for Weights and Measures Mode __40
Codes __80-__89 "1" for Program Mode __
__41 Blend Preset Display Enter: "0" Raw Preset (Raw) __41
"1" Gross Preset (Grs)
"2" Gross Preset at Standard Temperature (Gst)
"3" Gross Preset at Standard Temperature
and Pressure (Net)
"4" Mass Preset __
__42 Blend Deliver Display Enter: "0" Raw Delivery (Raw) __42
"1" Gross Delivery (Grs)
"2" Gross Delivery at Standard Temperature (Gst)
"3" Gross Delivery at Standard Temperature
and Pressure (Net)
"4" Mass Delivery __
__43 Product #1 Enter: Four digits in tenth __43
Percentage of a percent (e.g., 050.0). __ __ __ __
Note: Codes __43, __44, __45, and __46 must add up to 100 %.
__44 Product #2 Enter: Four digits in tenth __44
Percentage of a percent (e.g., 050.0). __ __ __ __
Note: Codes __43, __44, __45, and __46 must add up to 100 %.
__45 Product #3 Enter: Four digits in tenth __45
Percentage of a percent (e.g., 050.0). __ __ __ __
Note: Codes __43, __44, __45, and __46 must add up to 100 %.

Related product manuals