Program       Program 
Code Function Code  Description  Entry  Code 
 
16  Issue/Rev. 03 (8/97) 
036  4-20 Channel #4  Enter:  Two digit number indicating  036 
  Terminals 71 & 72    the use of this 4-20 Channel. 
    First digit: 
      "0" Channel Not Used 
      "1" Product 1 
      "2" Product 2 
      "3" Product 3 
      "4" Product 4 
    Second digit: 
      "0" Channel Not Used 
    "1" Temperature 
    "2" Pressure 
    "3" Density 
      (e.g., 11 indicates that this channel 
      would be used by product 1 for a temperature 
    input).    __ __ 
 
 
037  Additive Injector  Enter:  Four digit number indicating  037 
  #1 Plumbing    the products that this additive 
      injector is plumbed into. 
 
      1st digit - Product #1 
      2nd digit - Product #2 
      3rd digit - Product #3 
      4th digit - Product #4 
 
      A zero in the digit indicates 
      that the injector is not plumbed 
      into that product, a one indicates 
      that the injector is plumbed 
      into that product. (e.g., 1110 
      indicates that the injector is  
      plumbed into products 1, 2,and 3.)  __ __ __ __ 
 
Note: If that additive injector output is configured for use and this entry is "0000" the indication is that it is plumbed into the loading arm downstream 
of the metering system.