Program Program
Code Function Code Description Entry Code
Issue/Rev. 0.3 (8/97) 15
033 4-20 Channel #1 Enter: Two digit number indicating 033
Terminals 19 & 20 the use of this 4-20 Channel.
First digit:
"0" Channel Not Used
"1" Product 1
"2" Product 2
"3" Product 3
"4" Product 4
Second digit:
"0" Channel Not Used
"1" Temperature
"2" Pressure
"3" Density
(e.g., 11 indicates that this channel
would be used by product 1 for a temperature
input). __ __
34 4-20 Channel #2 Enter: Two digit number indicating 034
Terminals 22 & 23 the use of this 4-20 Channel.
First digit:
"0" Channel Not Used
"1" Product 1
"2" Product 2
"3" Product 3
"4" Product 4
Second digit:
"0" Channel Not Used
"1" Temperature
"2" Pressure
"3" Density
(e.g., 11 indicates that this channel
would be used by product 1 for a temperature
input). __ __
035 4-20 Channel #3 Enter: Two digit number indicating 035
Terminals 68 & 69 the use of this 4-20 Channel.
First digit:
"0" Channel Not Used
"1" Product 1
"2" Product 2
"3" Product 3
"4" Product 4
Second digit:
"0" Channel Not Used
"1" Temperature
"2" Pressure
"3" Density
(e.g., 11 indicates that this channel
would be used by product 1 for a temperature
input). __ __

Related product manuals