Program 
Code 
 
Function 
 
Code Description  Prod 1
 
Prod 2  Prod 3 Prod 4
 
60  Issue/Rev. 03 (8/97) 
444  High Temperature   Enter:  Four digits. The 
  Alarm    first digit indicates polarity. 
      First digit "0" = Positive 
      First digit "1" = Negative 
      The last three digits 
      indicate temperature in whole 
      degrees. (e.g., 0250 = + 250) 
      Temperature units are dependent 
      on entry made in code 441 
      An entry of 0999 (+999) will 
      disable this feature.  _____  _____  _____  _____  
 
 
445  Maintenance Temperature   Enter: Five digits. The 
      first digit indicates polarity. 
      First digit "0" = Positive 
      First digit "1" = Negative 
      The last four digits 
      indicate temperature in tenths 
      of degrees. An entry of -999.9 
      will disable this feature. 
      (e.g., 0085.0 = + 85.0)  _____._  _____._  _____._  _____._ 
 
 
446 Temperature Offset  Enter: Three digits.  First digit 
      must be "0" or "1" (0 = positive, 
      1 = negative).  Second and third 
      digits represent the offset temperature 
      in tenth degrees (e.g., 10.5 entered 
      will display at -0.5 degrees offset)  __ __.__   __ __.__  __ __.__  __ __.__ 
 
 
447  Low Density Alarm  Enter:  Four digits. The 
      range is from 0000 to 9999. 
      Density units are dependent 
      on entry made in code 445 
      of the Systems Directory 
      An entry of 0000 will disable 
      this feature.  _____ _____ _____ _____ 
 
 
448  High Density Alarm  Enter:  Four digits. The 
      range is from 0000 to 9999. 
      Density units are dependent 
      on entry made in code 445 
      of the Systems Directory 
      An entry of 0000 will disable 
      this feature.  _____ _____ _____ _____ 
 
 
449-499  Unassigned at Present