Program       Program 
Code Function Code  Description  Entry  Code 
 
44  Issue/Rev. 03 (8/97) 
807  Permissive #1  Enter:   "0" No Permissive 1    807 
      "1" Permissive 1 Transaction start only 
      "2" Permissive 1 Continuously 
      "3" Start Permissive 1 
      "4" Batch Permissive 1 
      "5" Remote Start  __ 
 
Note:  Option 5 requires hardware jumpers (see installation manual). 
 
 
808   Permissive #1   Enter:   Up to 20 characters    808 
  Message    for prompt message  
      (e.g., Connect Ground)  _______________ 
 
 
809  Restart After   Enter:   "0" Man Perm. 1 Start    809 
  Permissive #1 Met    "1" Auto Perm. 1 Start  __ 
 
 
810  Prompt Message  Enter:  Up to 20 characters    810 
      for prompt message if no 
      AC power is detected on the 
      AC Input Programmed for 
      Printer Tray Switch or 
      Master Reset (e.g., 
      Please Insert Ticket)  _______________ 
 
 
811   Permissive #2  Enter:   "0" No Permissive 2    811 
      "1" Permissive 2 Transaction start only 
      "2" Permissive 2 Continuously 
      "3" Start Permissive 2 
      "4" Batch Permissive 2 
      "5" Remote Stop  __ 
 
Note:  Option 5 requires hardware jumpers (see Installation Manual). 
 
 
812  Permissive #2   Enter:   Up to 20 characters    812 
  Message    for prompt message 
      (e.g., Connect Vapor)  _______________ 
 
 
813  Restart After   Enter:   "0" Man Perm. 2 Start    813 
  Permissive #2 Met    "1" Auto Perm. 2 Start  __ 
 
 
814  Additive #1 Message  Enter:  Up to nine characters    814 
      for Additive #1 Message on 
      the Product Receipt Ticket. 
    (e.g., Dye)  _______________