Program Program
Code Function Code Description Entry Code
44 Issue/Rev. 03 (8/97)
807 Permissive #1 Enter: "0" No Permissive 1 807
"1" Permissive 1 Transaction start only
"2" Permissive 1 Continuously
"3" Start Permissive 1
"4" Batch Permissive 1
"5" Remote Start __
Note: Option 5 requires hardware jumpers (see installation manual).
808 Permissive #1 Enter: Up to 20 characters 808
Message for prompt message
(e.g., Connect Ground) _______________
809 Restart After Enter: "0" Man Perm. 1 Start 809
Permissive #1 Met "1" Auto Perm. 1 Start __
810 Prompt Message Enter: Up to 20 characters 810
for prompt message if no
AC power is detected on the
AC Input Programmed for
Printer Tray Switch or
Master Reset (e.g.,
Please Insert Ticket) _______________
811 Permissive #2 Enter: "0" No Permissive 2 811
"1" Permissive 2 Transaction start only
"2" Permissive 2 Continuously
"3" Start Permissive 2
"4" Batch Permissive 2
"5" Remote Stop __
Note: Option 5 requires hardware jumpers (see Installation Manual).
812 Permissive #2 Enter: Up to 20 characters 812
Message for prompt message
(e.g., Connect Vapor) _______________
813 Restart After Enter: "0" Man Perm. 2 Start 813
Permissive #2 Met "1" Auto Perm. 2 Start __
814 Additive #1 Message Enter: Up to nine characters 814
for Additive #1 Message on
the Product Receipt Ticket.
(e.g., Dye) _______________