Program
Code
Function
Code Description Prod 1
Prod 2 Prod 3 Prod 4
62 Issue/Rev. 03 (8/97)
507-539 Unassigned at Present
540 Protection of Program Enter: "0" for Weights and Measures Mode
codes 580-589 "1" for Program Mode __ __ __ __
541 Compressibility Factor Enter: Five digit compressibility factor
used in calculating the CPL
(e.g., 39600 entered
represents 0.000039600) _______ _______ _______ _______
542 Vapor Pressure Enter: "0" Straight Line Approximation
Calculation "1" GPA Table TP-15 __ __ __ __
543 Low Vapor (P1) Enter: Four digits indicating
Pressure the low vapor pressure in PSIA, Bars
or kg/cm2 in tenths of pressure
units, (e.g., 006.0)
Pressure units are dependent
on entry made in code 541
of Systems Directory ____._ ____._ ____._ ____._
544 Low Product Vapor Enter: Four digits in Degrees
Pressure (P1) C or Degrees F that corresponds
Temperature to the low vapor pressure
in code 543.
First digit "0" = Plus Degrees
First digit "1" = Minus Degrees
(e.g., 1150=-150). Temperature units are
dependent on entry made in code 441
of the Systems Directory _____ _____ _____ _____
545 Middle Vapor Enter: Four digits indicating
Pressure (P2) the middle vapor pressure in PSIA, Bars
or kg/cm
2
in tenths of pressure
units, (e.g., 020.0)
Pressure units are dependent
on entry made in code 541
of the Systems Directory. ____._ ____._ ____._ ____._
Note: This entry must exceed the entry made is 543 or it will be ignored.