Issue/Rev. 0.3 (8/97)  63
546  Middle Product Vapor  Enter:  Four digits in Degrees 
  Pressure (P2)     C or Degrees F that corresponds 
  Temperature    to the middle vapor pressure 
      in code 545. 
      First digit "0" = Plus Degrees 
      First digit "1" = Minus Degrees 
      (e.g., 0030 = +030). Temperature units are 
      dependent on entry made in code 441 
      of the Systems Directory   _____  _____  _____  _____ 
 
 
547  High Vapor   Enter:  Four digits indicating 
  Pressure (P3)    the high vapor pressure in PSIA, Bars  
    or kg/cm
2
 in tenths of pressure  
      units, (e.g., 100.0) 
      Pressure units are dependent 
      on entry made in code 541 
      of the Systems Directory.  ____._ ____._ ____._ ____._ 
 
Note: This entry must not exceed the entry made in 545 or it will be ignored. 
 
 
548  High Product Vapor   Enter:  Four digits in Degrees 
  Pressure (P3)    C or Degrees F that corresponds 
  Temperature    to the high vapor pressure 
      in code 546. 
      First digit "0" = Plus Degrees 
      First digit "1" = Minus Degrees 
      (e.g., 0600 = +060). Temperature units are 
      dependent on entry made in 
      code 441 of the Systems 
      Directory  _____ _____ _____ _____ 
 
 
549  Maintenance Pressure  Enter:  Four digit maintenance 
      pressure to be used when a pressure 
      transducer is not installed, 
      in tenths of units (e.g., 150.0) 
      Pressure units dependent on 
      selection made in code 541 
      of the Systems Directory. 
      "0000" disables this feature.  ____.__ ____.__ ____.__ ____.__ 
 
 
550-599  Unassigned at Present