Sening®
Innovative Tank Truck Systems
EPE2-
Controller for Meter Draining System
EPE2
Installation Manual
MN F08 003 US / DOK-450E Rev. 1.03 / JS / jp / March 2010 19
3.7 Parameters in MultiFflow
No. Name Seal K
Factory
Setting
Meaning
Activation of EPE2 required for optional
residue discharge
Node number of EPE2 when activated
EPE2 request interval. Used to trigger
EPE2 inactivity monitor.
Activates an instruction for residue removal
in the event of product change.
Parameter currently not in use. In a future
program version will activate printout of a
receipt after residue removal.
control
1 : Off
2: Stand-alone
Activates an instruction for residue removal
in the event of product change.
3: EPE2 manual
As 2, however the wet leg sensor con-
nected to the EPE2 monitors the residue
removal. No restart of MultiFlow required
after residue removal.
4: EPE2 automatic
As 3, however "Autom. residue removal"
menu item (menu 8) includes the option to
control a pump for the measuring system
residue removal via the EPE2 output.
timeout
Timeout for the autom. draining of the
measuring system with the aid of the EPE2
in "EPE2 automatic" mode. Residue re-
moval stops automatically after this period.
receipt
Parameter currently not in use. In a future
program version will activate printout of a
receipt after residue removal.