 MN F08 003 US / DOK-450E  Rev. 1.03 / JS / jp / March 2010  21 
 
After carrying out the residue removal operation (for this period the MultiFlow is switched off 
by the residue removal controller) the MultiFlow starts up again and the driver must repeat 
the drop pre-set entries. The query as to whether residue removal has been carried out is 
this time confirmed by pressing the <F1> key. The confirmation is saved in the logbook. 
 
  If parameter 3.1.8.5.1 (residue removal control) is set to “3” and/or “4” the wet leg sensor 
connected to the EPE2 is continuously monitored to check whether residue removal has 
been carried out on the measuring system (complete discharge and refilling). If residue re-
moval is detected, this is recorded in the MultiFlow logbook. If residue discharge has been 
detected, the residue removal message is not displayed when switching between diesel and 
heating oil / heating oil with additives. If residue removal has not been detected, the corre-
sponding message is displayed. Delivery in this case is not started until the measuring sys-
tem has undergone residue removal. The MultiFlow does not need to be restarted in this 
case. 
 
  If parameter 3.1.8.5.1 is set to “4” it is also pos-
sible to control the residue removal from the 
measuring system from the MultiFlow using a 
residue removal pump. A suitable pump must be 
connected to the EPE2 output for this purpose. 
The "Autom. residue removal" menu item (menu 
8) can be used for removal of residue from the 
measuring system. It is controlled in accordance 
with the maximum operating time (parameter 
3.1.8.5.2), with the <START> and <STOP> keys. 
 
 
 
Parameters: Menu 8 
No.  Name  Seal  K 
Factory  
setting 
Meaning 
al 
Control of a residue discharge pump con-
nected to the EPE2. For this purpose the 
"EPE2 automatic" mode must be activated 
(parameter 3.1.8.5.1). 
 
Seal sense: 
K  Priority  Meaning 
2  M aster 
High security level due to additional checksum; 
parameter transfer from the chip card only possible when seal is broken ! 
Lowest security level; parameters which are not saved on the chip card 
 
-------------------
Press  START  to 
continue 
Press  STOP  to exit
-------------------
Residue removal  
t i meout 
. . . . .