TROUBLE SHOOTING
Heated section does not
operate
The mains switch is off, circuit
breaker or fuses are off at the
power board
Turn mains switch on and
check circuit breakers and
fuses
Heated section temperature
incorrect
Incorrect thermostat setting
Adjust (CW to increase temp)
Relocate or shield cabinet
Refrigerated section does not
operate/start
The mains isolating switch on
the wall, circuit breaker or
fuses are off at the power
board
Turn isolating switch circuit
breaker or fuses on
High condenser temperature
Refrigerated section is not cold
enough
Ventilation grills are blocked
Vacuum or remove blockage
Product blocking air grill
Evaporator coil fins blocked
Clean coil fins of debris etc.
Relocate or shield cabinet
Trays obstructing air flow
Re-position trays on shelves
Thermostat needs adjustment
Ambient temperature > 25C
Adjust store air conditioning
Condenser radiator blocked
Temperature probe damaged
Replace temperature probe
Defrost cycle not suitable
Adjust to match
environment
Have fans checked/replaced
Cabinet lights not working
Internal circuit breaker has
tripped
Have wiring checked and
reset circuit breaker
Float switch relay faulty
Temporary condition, no
remedy
Refrigerated section circulation
fan rattling
Build-up of ice in cabinet well
due to blocked drain or cabinet
not being level
Clear drain, level cabinet and
defrost ice
The table entries in italics indicate actions to be taken only by qualified Service
Personnel.