Part No. 22958 Rev. P June 2017 - 20 - Fusion, Food & Beverage Cabinet
SERVICING
Mains Lead
COMBINED FOOD & BEVERAGE CABINETS
-
SERVICING
The mains leads must only be replaced by the manufacturer, their service agent
or similarly qualified person, in order to avoid a hazard.
Lighting
COMBINED FOOD & BEVERAGE CABINETS
-
SERVICING
The lighting and low power circuits are protected by a circuit breaker on the
control gear chassis, located behind the front grill of the refrigerated section and
on the back of the heated section.
If the lights do not work but the rest of the cabinet is operating, get an electrician
to check the lighting circuits.
DO NOT service lights without isolating the cabinet by unplugging it from the
mains supply socket, or turning off the servicing isolation switch.
Light is provided by four strips of LEDs.
Before replacing an LED strip, check the power supply.
Individual LED modules cannot be replaced. A complete
light unit must be used. Note that the light units are not all
the same, so the correct type must be selected.
Remove the plastic cover to access the LED unit.
Connection is made with
a plug and socket.
Disengage the supply
lead from the faulty unit,
and reconnect it to the
replacement unit.
Replace the plastic
cover.
The LEDs are fed with a 700mA constant current. They consume
approximately 19W per metre of strip length.
The power supplies and driver modules are located on the control gear chassis,
behind the heated section and below the refrigerated section.
Continued on next page