Preset Settings (Pressure or RPM)
The preset button allows the operator to go to a pre-programmed pressure or  
RPM setting during operations. The setting will be shown in the message display. This 
procedure is to change the setting in the program.
Note: The engine must be running and the pump engaged interlock circuit 
must be closed (the THROTTLE READY LED must be on).
1. Press IDLE button.
  Result: Engine goes to idle RPM
2. Press MODE button to select which setting to change.
  Result: LED indicator goes on for mode selected.
Note: The message display must show IDLE before changing the preset.
3.  Press and hold PRESET button. (Continue to hold through step 4.)
  Result: Message display ashes then shows preset... after 5 seconds the current 
setting  shows.
4.  Press the INC DEC buttons to change preset setting.
5. Release PRESET button.
  Result: The new preset is programmed. Message display shows IDLE.
High Idle
The governor programming includes a high idle function. To activate the high idle 
set interlocks as called for by SOP (normally this would include the transmission in 
neutral and the parking brake on ). Set the High Idle switch to ON.
Note: The pump must NOT be engaged when using the high idle function 
and the THROTTLE READY LED will be off.
Change High Idle Setting
Note: The high idle is set at about 1000 RPM at the factory.
1.  With the engine running, set the high idle switch to ON.
2.  Press and hold PRESET button for 3 seconds.
  Result: Message display will ash the high idle setting.
3.  Keep pressing the PRESET button and press the INC/DEC buttons to set 
desired RPM.
4.   Release PRESET button to store the new high idle setting.