21
5. Press the INC button.
Result: P 4 ashes in the PUMP INTAKE display. The message display shows SET
TIME 10:30AM .
6. To Change the Time: (If not go to step 7.)
a. Press the MENU button.
Result: P 4 stops ashing. The message display shows the current time with the
AM or PM ashing.
b. Press the INC or DEC button to change AM or PM.
c. Press the MENU button.
Result: The minute ashes.
d. Press the INC or DEC button to change the minutes.
e. Press the MENU button.
Result: The hour ashes.
f. Press the INC or DEC button to change the hours.
g. Press and hold the SILENCE button to store new time.
Result: P 5 ashes in the PUMP INTAKE display. The message display shows
WARNING CODES.
7. Press the MENU button.
Result: P501 shows in the PUMP INTAKE display and the message display shows
the most recent error or fault code. The date and time that the error or fault code was
recorded scrolls in the message display.
8. Press the INC or DEC button to scroll through 20 stored error and fault codes.
Note: FMI codes are displayed starting at P521.
9. Press and hold the SILENCE button.
Results: P 1 ashes in the PUMP INTAKE display.
10. Press the INC or DEC button to scroll through the P-codes or press the SILENCE button
to exit programming mode.