Start-up | 6
M2320121_en | Installation instructions Pellet boiler PECO 47
6.2 Initial startup
6.2.1 Permitted fuels
Wood pellets
Wood pellets made from natural wood with a diameter of 6mm
Note on standards
EU: Fuel acc. to EN ISO 17225 - Part 2: Wood pellets class A1 / D06
and/or: ENplus / DINplus certification scheme
General note:
Before refilling the store, check for pellet dust and clean if necessary.
TIP: Fit the Froling PST pellet deduster for separating the dust particles contained in the
return air
6.2.2 Non-permitted fuels
The use of fuels not defined in the "Permitted fuels" section, and particularly the burning
of refuse, is not permitted.
CAUTION
In case of use of non-permitted fuels:
Burning non-permitted fuels increases the cleaning requirements and leads to a
build-up of aggressive sedimentation and condensation, which can damage the
boiler and also invalidates the guarantee. Using non-standard fuels can also lead
to serious problems with combustion.
For this reason, when operating the boiler:
r Only use permitted fuels
6.2.3 Heating up for the first time
NOTICE
If condensation escapes during the initial heat-up phase, this does not indicate a fault.
r Tip: If this occurs, clean up using a cleaning rag.
NOTICE!See boiler controller instruction manual for all the steps necessary to