IMPORTANT! In order for the USB logging function to work correctly the time must be set
correctly. Setting the time is discussed in the section "Menu items in the Setup menu" -
"Time / Date".
Relay (floating
contact switch)
Status codes (state codes), the status of the inverter (e.g. feeding energy into the grid) or
Energy Manager functions can be displayed using the floating switch contact (relay).
* these are only shown if the "E-Manager" function has been activated under "Relay mode".
Logging interval
Activate / deactivate the USB logging function and specify a logging interval
Unit Minutes
Setting range 30 min. / 20 min./ 15 min./ 10 min./ 5 min./ No log
Factory setting 30 min.
30 min. The logging interval is 30 minutes; every 30 minutes new log-
ging data will be saved to the USB flash drive.
20 min.
15 min.
10 min.
5 min. The logging interval is 5 minutes; every 5 minutes new logging
data will be saved to the USB flash drive.
No log No data is saved
Setting range Relay mode / Relay test / Switch-on point* / Switch-off point*
Relay mode
The following functions can be shown using relay mode:
- Alarm function (Permanent / ALL / GAF)
- Active output (ON / OFF)
- Energy Manager (E-Manager)
Setting range ALL / Permanent / GAF / OFF / ON / E-Manager
Factory setting ALL
Alarm function:
ALL / Perma-
nent:
Switching the floating switch contact for permanent and temporary
service codes (e.g. brief interruption to energy being fed into the grid,
a service code occurs a certain number of times a day - can be adjust-
ed in the "BASIC" menu)