EasyManuals Logo

Fronius Primo 8.2-1 User Manual

Fronius Primo 8.2-1
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
9
EN
Text of the warning notices:
WARNING!
An electric shock can be fatal. Make sure that both the input side and output side of the
device are de-energised before opening the device. Wait for the capacitors to discharge (5
minutes).
Notes for a dum-
my device
A dummy device is not suitable for the operative connection to a photovoltaic system and
may only be taken into operation for demonstration purposes.
IMPORTANT! With a dummy device never connect live DC cables to the DC terminals.
Attaching not-energized cables or cable pieces for demonstration purposes is permitted.
A dummy device can be identified by the device rating plate:
Example: Device rating plate of a dummy device
Safety symbols:
Risk of serious injury and damage
due to incorrect operation
Do not use the functions de-
scribed here until you have fully
read and understood the following
documents:
- These Operating Instructions
- All the Operating Instructions
for the system components of
the photovoltaic system, es-
pecially the safety rules
Dangerous electrical voltage
Wait for the capacitors to dis-
charge.
5
5
5
5
5

Table of Contents

Other manuals for Fronius Primo 8.2-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Primo 8.2-1 and is the answer not in the manual?

Fronius Primo 8.2-1 Specifications

General IconGeneral
AC Nominal Output Power8200 W
Frequency50 / 60 Hz
Dimensions (Height x Width x Depth)645 x 431 x 204 mm
Protection ClassIP65
Max. Apparent AC Power8.2 kVA
THD< 3%
DC Input Voltage Range200 - 800 V
Number of MPP Trackers2
DC ConnectionMC4
Nominal AC Voltage230 V
AC ConnectionScrew terminal
Operating Temperature Range-25°C - +60°C