EasyManua.ls Logo

Fronius Primo GEN24 6.0 Plus - Integrated DC Disconnector

Fronius Primo GEN24 6.0 Plus
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8) Valid for Fronius Primo GEN24 with battery connection and Fronius Primo
GEN24 Plus.
9) Specified values are standard values; depending on the requirement and
PV power, these values must be adjusted accordingly.
10) Specified value is a max. value; exceeding the max. value may negatively
affect the function.
11) Software class B (single-channel with periodic self-test) per IEC 60730-1
Annex H.
Integrated DC
disconnector
General data
Product name Benedict LS32 E 7905
Rated insulation voltage 1000 V
DC
Rated impulse withstand voltage 8 kV
Suitability for insulation Yes, DC only
Utilisation category and / or PV utilisation
category
In accordance with IEC/EN
60947-3 utilisation category
DC-PV2
Rated short-time withstand current (l
cw
) Rated short-time withstand cur-
rent (l
cw
): 1000 A
Rated short-circuit making capacity (l
cm
) Rated short-circuit making capa-
city (l
cm
): 1000 A
Rated operating current and rated breaking capacity
Rated operating
voltage (U
e
)
Rated operating
current (l
e
)
I
(make)
/
I
(break)
Rated operating
current (l
e
)
I
(make)
/
I
(break)
≤ 500 V
DC
14 A 56 A 36 A 144 A
600 V
DC
8 A 32 A 30 A 120 A
700 V
DC
3 A 12 A 26 A 88 A
800 V
DC
3 A 12 A 17 A 68 A
900 V
DC
2 A 8 A 12 A 48 A
1000 V
DC
2 A 8 A 6 A 24 A
Number of pins 1 1 2 2