Select the cable cross section in ac-
cordance with the instructions in Per-
missible cables for the electrical con-
nection from page 67.
Strip the insulation of the individual
conductors by 12 mm. Lift to open the
terminal's operating lever and insert
the stripped single conductor into the
slot provided, in each case as far as it
will go. Then close the operating lever
until it engages.
WARNING!
Danger due to individual conductors in
the terminal that are loose and/or im-
properly connected.
This can result in serious injury and
damage to property.
▶
Only connect one single conductor
in the slot provided for each ter-
minal.
▶
Check that the single conductor is
held securely in the terminal.
▶
Ensure that all of the single con-
ductor is within the terminal and
that no individual wire strands are
sticking out of the terminal.