Fronius system monitoring settings
Settings on the
Fronius system
monitoring web-
site
If the battery is installed at a later date or the inverter was only updated to software version
1.9.x-x after the system had already been commissioned, several settings will need to be
changed on the system monitoring website. In the "IO mapping" section, a pin must be se-
lected under "Energy storage system". The battery must be selected in the "System over-
view" area.
Creating IO map-
ping
Enable "Energy storage system" under Settings - IO mapping. The pin assignment
must match the cabling.
System monitor-
ing settings
Select "RESU7H / RESU10H" in the Battery field under Settings - System overview
Select "activated" in the Meter field. The meter position must be selected under Set-
tings depending on the installation (consumption branch or feed-in point)
If the Checkbox has been installed correctly, check the box next to "Fronius Checkbox
500V installed"
1
1
2
3