The set-up menu
Adjust the following parameters within the set-up menu
- Arc force (for the rod-electrode welding process)
- Characteristic (for the rod-electrode welding process with CEL electrodes)
- TIG Comfort Stop (for the TIG welding process - TP 1500 TIG only)
- Frequency (for the TIG pulsed-arc welding process - TP 1500 TIG only)
Function prin-
ciple
The parameters are a 4-stage setting on the TP 1500 / TP 1500 RC, and a 5-stage
setting on the TP 1500 TIG.
The numbers of indicators that have lit up correspond to the setting value (stage).
Indicators light up: Einstellung
None Stage 0
One Stage 1
Two Stage 2
Three Stage 3
Four (TP 1500 TIG Only) Stage 4
Fig.11 Example of stage indication (only applicable to TP 1500 TIG)
Stage 3
Example: if three indicators are lit up, the setting is on
Stage 3
Setting the
parameters
The following example of how to set a parameter is for the rod-electrode welding pro-
cess, as illustrated by the arc-force parameter.
- Select the rod-electrode welding process (10) by pressing and
holding the process button (6)
- The pre-set stage is indicated for 1 second
As long as you hold the process-button (6), the arc-force parame-
ter will be increased by one stage per second.
- As soon as the desired stage is indicated
- Release the process button (6)
(6)
(10)
- The setting-value (stage) for the arc-force parameter is stored
- The rod-electrode welding process is indicated
Important! Even if you unplug the machine from the mains, the selected parameters
will still be stored.
Possible settings
and adjustments

Table of Contents

Related product manuals