16
The set-up menu
Adjust the following parameters within the set-up menu
- Arc force (for the rod-electrode welding process)
- Characteristic (for the rod-electrode welding process with CEL electrodes)
- TIG Comfort Stop (for the TIG welding process - TP 1500 TIG only)
- Frequency (for the TIG pulsed-arc welding process - TP 1500 TIG only)
Function prin-
ciple
The parameters are a 4-stage setting on the TP 1500 / TP 1500 RC, and a 5-stage
setting on the TP 1500 TIG.
The numbers of indicators that have lit up correspond to the setting value (stage).
Indicators light up: Einstellung
None Stage 0
One Stage 1
Two Stage 2
Three Stage 3
Four (TP 1500 TIG Only) Stage 4
Fig.11 Example of stage indication (only applicable to TP 1500 TIG)
Stage 3
Example: if three indicators are lit up, the setting is on
Stage 3
Setting the
parameters
The following example of how to set a parameter is for the rod-electrode welding pro-
cess, as illustrated by the arc-force parameter.
- Select the rod-electrode welding process (10) by pressing and
holding the process button (6)
- The pre-set stage is indicated for 1 second
As long as you hold the process-button (6), the arc-force parame-
ter will be increased by one stage per second.
- As soon as the desired stage is indicated
- Release the process button (6)
(6)
(10)
- The setting-value (stage) for the arc-force parameter is stored
- The rod-electrode welding process is indicated
Important! Even if you unplug the machine from the mains, the selected parameters
will still be stored.
Possible settings
and adjustments