Questions and Answers

  • A
    Austin PhillipsAug 17, 2025
    What to do if the Fronius TransTig 800 displays 'Ignition time-out'?
    • J
      Jennifer ChambersAug 18, 2025
      If the Fronius Welding System indicates an 'Ignition time-out', it means the current didn't start flowing before the set wire length was fed, and the power source safety cut-out was activated. Try pressing the torch trigger repeatedly. Also, clean the workpiece surface. If the problem persists, increase the time until the safety cut-out is triggered via the level 2 setup menu.
  • C
    Courtney NguyenAug 20, 2025
    What to do if Fronius Welding System shows error 'PE'?
    • C
      Connie GallagherAug 20, 2025
      If your Fronius Welding System displays error 'PE', the earth current watchdog has triggered the power source's safety cut-out. To resolve this, switch off the power source, wait 10 seconds, and then switch it back on. If the error continues after several attempts, the provided information is insufficient to resolve this issue.
  • M
    monicacisnerosAug 22, 2025
    What to do if Fronius Welding System tP1 error occurs?
    • M
      Michelle DudleyAug 22, 2025
      If the Fronius Welding System displays a tP1 error, it indicates overtemperature in the power source's primary circuit. Allow the power source to cool down.
  • S
    sandyhenryAug 25, 2025
    What to do if Fronius TransTig 800 Welding System tP2 error occurs?
    • D
      Derek GrayAug 26, 2025
      If the Fronius Welding System displays a tP2 error, it indicates overtemperature in the power source's primary circuit. Allow the power source to cool down.
  • B
    byrdjoshuaAug 27, 2025
    What to do if Fronius TransTig 800 Welding System tP3 error occurs?
    • B
      Brad SmithAug 27, 2025
      If the Fronius Welding System displays a tP3 error, it indicates overtemperature in the power source's primary circuit. Allow the power source to cool down.
  • G
    gregory86Aug 30, 2025
    What to do if Fronius TransTig 800 Welding System tP4 error occurs?
    • M
      Marilyn VincentAug 30, 2025
      If the Fronius Welding System displays a tP4 error, it indicates overtemperature in the power source's primary circuit. Allow the power source to cool down.
  • R
    Robert RuizSep 1, 2025
    What to do if Fronius Welding System tP5 error occurs?
    • H
      hilljosephSep 2, 2025
      If the Fronius Welding System displays a tP5 error, it indicates overtemperature in the power source's primary circuit. Allow the power source to cool down.
  • L
    lawrenceoconnellSep 3, 2025
    What to do if Fronius TransTig 800 Welding System tP6 error occurs?
    • J
      Joseph BellSep 4, 2025
      If the Fronius Welding System displays a tP6 error, it indicates overtemperature in the power source's primary circuit. Allow the power source to cool down.
  • D
    David OliverSep 6, 2025
    What to do if Fronius Welding System tS1 error occurs?
    • A
      Angela ThompsonSep 6, 2025
      If the Fronius Welding System displays a tS1 error, it indicates overtemperature in the power source's secondary circuit. Allow the power source to cool down.
  • K
    karen12Sep 9, 2025
    What to do if Fronius Welding System tS2 error occurs?
    • K
      Kimberly LewisSep 9, 2025
      If the Fronius Welding System displays a tS2 error, it indicates overtemperature in the power source's secondary circuit. Allow the power source to cool down.