IMPORTANT The following points apply to the pulsed welding current:
The power source automatically regulates the pulsing parameters as a function of the pre-
set main current I
1
.
The pulsed welding current begins:
- after the end of the starting-current phase I
S
- with the upslope phase UPS
Depending on what tAC time has been set, the pulsed welding current may continue up to
and including the final current phase I
E
(tAC set-up parameter set to "ON").
After the tAC time has elapsed, welding continues at a constant welding current, and any
pulsing parameters that may have been set continue to be available.