- 20 -
5. Change of load measuring method
The initial setting of loads (final loads, press-fit loads) to be measured and judged is peak value. The following procedure
shows the method of changing the value to instantaneous value:
For peak value and instantaneous value, please refer to “Technical terms” in page 2.
1. Push 5
F
key
Letters marked with mesh are flashed.
In the case that letters other than “ ” are displayed, p
ush RESET key.
2. Push SET/CHG key
3. Push 2
MODE
key
This indicates selection mode for load measuring.
4. Push SET/CHG key
This shows that present measuring mode is for peak value
.
5. For switching to instantaneous
value mode, Push 0 key.
←The measuring at present shows instantaneous mode “ ”.
6. Push SET/CHG key
7. Push RESET key
The mode has been changed from peak value to instantaneous value.
In the case that the mode shall be returned from instantaneous value mode to peak value mode, please push [ 1 key in
process 5. When changing the mode, confirmation by using load measuring display lamp (peak, instantaneous) is not
possible. After the mode is switched, operate press one process to “Safety one process.” Display lamp flashes during
pressurizing and lights up at the completion of pressurizing.
◎If [Reset] key is pushed prior to pushing [SET/CHG] key in the above 6, all operations made so far are cancelled.