Instruction Manual
DeviceNet Interface Option
"OPC-E1-DEV"
Thank you for purchasing our DeviceNet Interface Option OPC-E1-DEV.
This product is designed to connect the FRENIC-Multi series of inverters to DeviceNet. Read through this
instruction manual and be familiar with the handling procedure for correct use.
Improper handling blocks correct operation or causes a short life or failure.
Deliver this manual to the end user of the product. The end user should keep this manual in a safe place
until the DeviceNet Interface Option is discarded.
For the usage of inverters, refer to the instruction manual prepared for the FRENIC-Multi series of inverters.
Fuji Electric FA Components & Systems Co., Ltd.

Questions and Answers

  • T
    Tom BrownAug 1, 2025
    What to do if the NS LED lights in red on Fuji Electric FRENIC-Multi OPC-E1-DEV Control Unit (er5 alarm cannot be reset)?
    • J
      John JacksonAug 1, 2025
      If the NS LED lights up red and the er5 alarm cannot be reset on your Fuji Electric Control Unit, the issue might stem from several causes. First, ensure the node address is unique to prevent conflicts in DeviceNet. Next, verify that the baud rate settings match. Also, confirm that the 24 V power supply is correctly connected. Inspect the DeviceNet cabling for any issues and correct them. Finally, power cycle both the inverter and the option after making any DIP switch modifications.
  • L
    Lisa SchroederAug 5, 2025
    What to do if the NS LED blinks in red on Fuji Electric FRENIC-Multi OPC-E1-DEV (er5 alarm has occurred)?
    • C
      charles07Aug 5, 2025
      If the NS LED is blinking red on your Fuji Electric Control Unit and the er5 alarm has occurred, it could be due to a broken cable during communication. In this case, repair or replace the broken cable. Another potential cause is that the I/O scan interval is too short. Try increasing the I/O scan interval to resolve the issue.
  • J
    Joseph JohnsonAug 9, 2025
    What to do if none of the LEDs on the Fuji Electric FRENIC-Multi OPC-E1-DEV Control Unit option light up?
    • A
      Anita JohnsonAug 9, 2025
      If none of the LEDs on the Fuji Electric Control Unit option are lighting up, the problem may be due to a disconnected 24 VDC power supply. Check to ensure that a 24 VDC power supply is properly connected. If the power supply is connected and the LEDs still don't light, the option itself might be faulty and need replacement.
  • K
    Kayla PerryAug 14, 2025
    Why the NS LED would not light on Fuji Electric Control Unit?
    • C
      Curtis AlvaradoAug 14, 2025
      If the NS LED is not lighting up on your Fuji Electric Control Unit, it could be due to an improper node address setting for the option. Correct the node address for the option. Another potential cause is a broken cable for DeviceNet communications. Repair or replace the broken DeviceNet communication cable.
  • C
    Christopher GreerAug 17, 2025
    What to do if er4 alarm cannot be reset on Fuji Electric FRENIC-Multi OPC-E1-DEV (The MS LED lights in red)?
    • M
      Matthew MercerAug 17, 2025
      If the er4 alarm cannot be reset and the MS LED is red on your Fuji Electric Control Unit, the option might not be properly mounted. Ensure that the option is correctly mounted. Another possible cause is that the option connection cable is not connected. Connect the option connection cable. If the problem persists, the option might be faulty and require replacement.
  • R
    raykevinAug 22, 2025
    Why the NS LED keeps blinking in green and does not stay on in green on Fuji Electric FRENIC-Multi OPC-E1-DEV Control Unit?
    • I
      icortezAug 23, 2025
      If the NS LED keeps blinking green and does not stay on green on your Fuji Electric Control Unit, it could be because the master is not requesting a connection. Ensure the master requests a connection. The I/O scan interval might also be set too short at the start of communication; set a longer I/O scan interval. Additionally, the I/O area might be invalidly mapped; correct the I/O area mapping. Finally, there might be no I/O connection; establish the I/O connection.
  • R
    rholmesAug 27, 2025
    What to do if the settings for run command or speed command cannot be validated even though the NS LED lights in green on Fuji Electric Control Unit?
    • D
      Diana PorterAug 27, 2025
      If the settings for the run command or speed command cannot be validated even though the NS LED lights in green on your Fuji Electric Control Unit, verify that either NetCtrl or NetRef is set to "1." Also, check if a higher-priority run command or speed command is enabled on the inverter and disable it. Ensure that the selection of I/O Assembly Instances is correct. Finally, power OFF and then ON the inverter and the option after modifying the o31 data.

Summary

Preface

How this manual is organized

Overview of the manual's chapter structure and content.

Related Publications

Lists other manuals relevant to the DeviceNet interface option.

Safety precautions

Details important safety information and warnings for using the product.

Operational Procedures

Installation and Wiring

Instructions for installing and wiring the DeviceNet interface option.

Operation

Guidance on operating the inverter with the DeviceNet interface option.

Maintenance and Inspection

Procedures for maintaining and inspecting the DeviceNet option.

Disposal

Others

Chapter 1: Before Using This Option

1.1 Acceptance Inspection

Checks to be performed upon delivery of the DeviceNet interface option and accessories.

1.2 Applicable Inverters

Lists the FRENIC-Multi inverters and ROM versions compatible with the option.

Chapter 2: Basic Functions and Settings

2.1 DeviceNet Interface Option Inside View

Illustrates the internal components of the DeviceNet interface option.

2.2 DIP Switch

Configures communication data rate and node address using the DIP switch.

2.3 LED Status Indicators

Details the meaning of the MS and NS LEDs indicating hardware and network status.

2.4 RJ-45 Connector and Terminal Blocks

Covers RJ-45 connector and terminal blocks for power and DeviceNet connections.

Chapter 3: Installation of This Option

Chapter 4: Wiring and Cabling

4.1 Basic Connection Diagram

Illustrates the fundamental wiring connections for the FRENIC-Multi and DeviceNet option.

4.2 Wiring for Power Supply Terminal Block

Details the wiring procedures for the 24V power supply terminal block.

4.3 Wiring for DeviceNet Terminal Block

Explains the wiring connections for the DeviceNet communication cable.

4.4 Turning ON the Optional 24 V Power Supply

Provides instructions on the correct ON/OFF timing for the option and inverter.

Chapter 5: Configuring Inverters Function Codes for DeviceNet Communication

Chapter 6: Establishing a DeviceNet Communications Link

Chapter 7: I;O Message

7.1 Overview

Explains I/O Message as a cyclic communication process between master and slave.

7.2 I;O Assembly Instances: Selection and Setup

Details the selection and setup of I/O assembly instances for various control modes.

7.3 An Example of Actual I;O Communication Data

Provides a practical example of I/O data in Extended Speed Control Instance.

Chapter 8: Explicit Message

8.1 Overview

Explains Explicit Message for arbitrary access to DeviceNet variables and function codes.

8.2 Objects to be Used in Explicit Message

Describes objects related to the option and inverter for explicit message communication.

8.3 Error Code List for Explicit Message Errors

Lists explicit message errors, their codes, descriptions, and recovery methods.

Chapter 9: Inverter Reaction to DeviceNet Communications Errors

Chapter 10: Alarm Code List

Chapter 11: Troubleshooting

Chapter 12: Specifications

12.1 General Specifications

Lists general specifications of the DeviceNet interface option and applicable inverter.

12.2 DeviceNet Specifications

Details the specifications related to DeviceNet communication protocols and capabilities.