5-69
input phase loss protection, (c) output phase loss protection, and (d) judgment on the life of
the DC link bus capacitor, as well as specifying the judgment threshold on the life of the DC
link bus capacitor, in a style of combination (Bit 0 to Bit 4).
Automatic lowering of carrier frequency (Bit 0)
This function should be used for important machinery that requires keeping the inverter
running.
Even if a heat sink overheat or overload occurs due to excessive load, abnormal ambient
temperature, or cooling system failure, enabling this function lowers the carrier frequency to
avoid tripping (
J
or
NWX
). Note that enabling this function results in increased motor
noise.