– 35 –
Parameter :
[Table 5] Control operation type code
[Description of functions]
1. Power ON start: Starts ramp/soak with the current PV value.
2. Output at END: Displays the output status at the time when ramp/soak is at END.
3. Output at OFF: Displays the output status at the time when ramp/soak is at OFF.
4. Repeat operation: After the ramp/soak step is terminated once, runs ramp/soak repeatedly.
The PV value set in the previous step is maintained in normal state (without repeat operation).
* Standby mode: Output
-
3%
Alarm OFF
Standby mode where no control operation is performed.
MOD
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Power ON start
Without
Without
Without
Without
Without
Without
Without
Without
With
With
With
With
With
With
With
With
Output at END
Control continued
Control continued
Control continued
Control continued
Standby mode
Standby mode
Standby mode
Standby mode
Control continued
Control continued
Control continued
Control continued
Standby mode
Standby mode
Standby mode
Standby mode
Output at OFF
Control continued
Control continued
Standby mode
Standby mode
Control continued
Control continued
Standby mode
Standby mode
Control continued
Control continued
Standby mode
Standby mode
Control continued
Control continued
Standby mode
Standby mode
Repeat operation
Without
With
Without
With
Without
With
Without
With
Without
With
Without
With
Without
With
Without
With
[MOD code list]